Sorry, you need to enable JavaScript to visit this website.

Purification of nickel or cobalt ion containing effluents by electrolysis on reticulated vitreous carbon cathode

TitoloPurification of nickel or cobalt ion containing effluents by electrolysis on reticulated vitreous carbon cathode
Tipo di pubblicazioneArticolo su Rivista peer-reviewed
Anno di Pubblicazione2014
AutoriDell'Era, A., Pasquali M., Lupi C., and Zaza F.
RivistaHydrometallurgy
Volume150
Paginazione1-8
ISSN0304386X
Parole chiaveCobalt ion, Dimensionless analysis, Electrochemical filter, Nickel and cobalts, Reticulated vitreous carbon
Abstract

The study is aimed at improving a methodology to purify nickel or cobalt ion containing effluents by an electrochemical filter. Consequently, a cell with reticulated vitreous carbon (RVC) cathode for Ni and Co depletion was designed to analyze, at room temperature and pH equal to 6, flowrates and cathodic potentials able to affect the electrochemical process. Starting with Ni and Co initial concentration of 150 ppm, it is possible to reach a concentration lower than 0.1 ppm for both metals in less than 1 h, with a flowrate of about 1300 ml/min and for a catholyte volume of 1000 ml, under mass transport control conditions (for Ni - 1.1 V and for Co - 1.2 V cathodic potential versus Standard Calomel Electrode (SCE)). Moreover, the proposed work studied the process kinetics and fluid dynamics through the use of dimensionless relations such as Reynolds and Sherwood numbers. In addition considerations on current efficiency for reduction of both metal ions were done. © 2014 Elsevier B.V.

Note

cited By 2

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84907533282&doi=10.1016%2fj.hydromet.2014.09.001&partnerID=40&md5=b657efc695a239ecfb53807a465232e4
DOI10.1016/j.hydromet.2014.09.001
Citation KeyDell'Era20141