Sorry, you need to enable JavaScript to visit this website.

Ultrasonic analysis and lock-in thermography for debonding evaluation of composite adhesive joints

TitoloUltrasonic analysis and lock-in thermography for debonding evaluation of composite adhesive joints
Tipo di pubblicazioneArticolo su Rivista peer-reviewed
Anno di Pubblicazione2016
AutoriPalumbo, Domenico, Tamborrino R., Galietti U., Aversa Patrizia, Tatì Angelo, and Luprano Vincenza A. M.
RivistaNDT and E International
Volume78
Paginazione1-9
ISSN09638695
Parole chiaveAbility testing, Accelerated aging, Adhesive joints, Composite adhesive joints, Fiber reinforced, Fiber reinforced plastics, glass, Glass fiber reinforced plastics, Glass fibers, Lockin thermography, Locks (fasteners), Plastic adhesives, Quality control, Reinforcement, Static tensile, Thermographic analysis, Thermography (imaging), Thermography (temperature measurement), Ultrasonic analysis, Ultrasonic applications, Ultrasonic C-scan, Ultrasonic imaging, Ultrasonic testing
Abstract

Glass-fiber reinforced thermosetting plastic adhesive joints were characterized through ultrasonic imaging and lock-in thermographic analysis for assessing the adhesion quality before being subjected to static tensile mechanical tests and to accelerated aging cycles. The mapping of each sample has been obtained. Visual testing were performed on all specimens after the mechanical tests in order to obtain a comparison with ultrasonic and lock-in thermography technique. A quantitative analysis has been carried out to evaluate the ability of lock-in thermography in investigating inadequate bonding and obtaining the validation of the technique by the consistency of the results with the well-established ultrasonic testing. © 2015 Published by Elsevier Ltd.

Note

cited By 10

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84947716147&doi=10.1016%2fj.ndteint.2015.09.001&partnerID=40&md5=5a883965693a2db9103a4c0fdbc3d0ef
DOI10.1016/j.ndteint.2015.09.001
Citation KeyPalumbo20161